Annals of the Academy of Romanian Scientists
Series on Science and Technology and Information
Online ISSN 2066-8562 Volume 19, Number 2/2026 54
COMPARATIVE EVALUATION OF DEEP-LEARNING
ARCHITECTURES FOR 3D THORACIC ORGAN-AT-RISK
SEGMENTATION ON PRIVATE CLINICAL CT DATA
Denisa-Daniela FRIMU-PASCU
1
, Ciprian DOBRE
2
Abstract. Automatic segmentation of thoracic organs at risk (OARs) can reduce
contouring burden in radiotherapy, but performance depends on architecture, training
recipe, and annotation availability. In this, we compared nnU-Net, STU-Net-S, MedNeXt-
S, and TotalSegmentator-initialized STU-Net-B on a fixed private thoracic CT cohort of
159 evaluable cases and 15 OARs. The mean Dice was 0.653, 0.725, 0.734, and 0.748,
respectively, with STU-Net-B being ranked highest across all organs, whereas MedNeXt-S
led on better-supported structures. Thus, we demonstrate that model ranking is anatomy-
and evidence-support-dependent, supporting organ-aware rather than single-score model
selection.
Keywords: medical image segmentation; thoracic CT; organs at risk; nnU-Net; STU-Net;
MedNeXt; radiotherapy; partial annotation
DOI 10.56082/annalsarsciinfo.2026.2.54
1. Introduction
Accurate delineation of organs at risk is an important component of radiotherapy
planning. Manual contouring requires substantial clinical effort and is affected by
anatomical complexity, image quality, observer variability, treatment-specific
requirements, and the number of structures that must be reviewed. Deep-learning-based
segmentation, on the other hand, offers the possibility of reducing repetitive contouring
work while provâiding consistent initial anatomical delineations for expert review.
U-shaped convolutional neural networks established the dominant architectural
paradigm for biomedical image segmentation [1], while volumetric extensions
demonstrated the benefit of using three-dimensional spatial context when processing
medical images [2]. More recent systems have moved beyond a single fixed U-Net
design. nnU-Net introduced a self-configuring approach in which preprocessing, patch
geometry, architecture and training parameters are adapted to dataset characteristics
[3]. STU-Net subsequently investigated systematic scaling and transfer learning for
three-dimensional medical segmentation [4], while MedNeXt modernised volumetric
convolutional networks using ConvNeXt-inspired residual blocks and large-kernel
1
PhD Student, Doctoral School of Automatic Control and Computers, National University of
Science and Technology POLITEHNICA Bucharest, Bucharest, Romania.
2
Prof., Faculty of Automatic Control and Computers, National University of Science and
Technology POLITEHNICA Bucharest, Bucharest, Romania, (ciprian.dobre@upb.ro).
3D Thoracic OAR Segmentation Comparison 55
processing [5]. Large multi-organ resources such as TotalSegmentator have
additionally created opportunities for supervised pretraining across broad anatomical
label spaces [6].
These developments raise an important practical question: does a more recent or larger
architecture consistently provide superior performance when transferred to
heterogeneous clinical radiotherapy data?
Answering this question is less straightforward than comparing one global Dice score.
Real retrospective clinical contour archives differ substantially from curated research
benchmarks. Not every structure is delineated in every patient, because contours are
created according to treatment purpose, anatomical coverage and clinical need. Missing
annotation therefore cannot automatically be interpreted as absence of the anatomical
structure. Partial-label learning research has shown that treating unlabelled structures
as conventional background may introduce incorrect supervision [7].
Evaluation is similarly affected. A global average can combine structures with very
different anatomical characteristics and very different numbers of available reference
contours. Metric-selection frameworks emphasise that segmentation performance
should be interpreted according to the target anatomy, reference data, error
characteristics and intended use rather than through a single universal metric [8].
The present study reports a comparative evaluation performed during doctoral research
on private clinical radiotherapy CT data. Four three-dimensional segmentation
configurations were evaluated:
1. nnU-Net v2 3D full-resolution as the reference configuration;
2. STU-Net-S trained from random initialisation;
3. MedNeXt-S trained from random initialisation;
4. STU-Net-B initialised from TotalSegmentator-pretrained weights.
The primary objective was to compare these configurations on the same fixed thoracic
evaluation cohort using structure-specific ground-truth denominators. A second
objective was to determine whether the apparent ranking of the models remained stable
when the analysis was restricted to structures supported by larger numbers of annotated
cases.
The central hypothesis was that model performance would be anatomy dependent and
evaluation dependent, such that no architecture could be considered universally
superior from a single aggregate score.
56 Denisa-Daniela FRIMU-PASCU, Ciprian DOBRE
2. Material and method
2.1. Clinical imaging data
The experimental data originated from a private retrospective radiation-oncology
imaging archive. The three-dimensional experimental programme contained 156
prepared model-development cases according to the executable dataset metadata.
A separate fixed evaluation registry contained 160 thoracic patient records. One record
could not be reconstructed because the corresponding raw DICOM CT data were
unavailable and was permanently excluded before final scoring. The resulting
evaluation cohort contained 159 evaluable thoracic cases.
The 15-structure segmentation ontology consisted of: heart, left lung, right lung, spinal
cord, esophagus, liver, left kidney, right kidney, trachea, thyroid, stomach, pancreas,
spleen, aorta, and duodenum. The presence of upper-abdominal structures reflects the
anatomical coverage of thoracic radiotherapy CT acquisitions and the contours
available in the clinical archive. The clinical data were de-identified for research
analysis and were used under the confidentiality and research-data-use arrangements
established for the doctoral research.
2.2. Annotation availability
The clinical archive was partially annotated. Consequently, all 15 structures were not
available as reference contours in every CT study. The numbers of cases containing
valid ground-truth contours ranged from 159 for the spinal cord to only 8 for the
duodenum. Heart and lungs were represented in most cases, whereas several upper-
abdominal and less routinely delineated structures had substantially smaller
denominators. In our case, a missing contour was not treated as evidence that the
anatomical structure was absent. Standard overlap metrics were therefore calculated
only for cases in which a valid reference contour for the corresponding structure was
available.
The study documentation describes a multidisciplinary annotation workflow involving
radiotherapy physicians, radiation-oncology residents, a clinical oncologist and a
medical physicist, including review of initial contours and resolution of disagreements
through discussion. However, a complete quantitative inter-observer analysis was not
available and is therefore not claimed in this study.
2.3. DICOM conversion and preprocessing
Source CT series and RTSTRUCT contours were converted to volumetric image-label
representations for three-dimensional processing. In particular, DICOM CT slices were
ordered according to physical slice-position metadata rather than file names. During
technical quality assurance, a z-orientation problem affecting an earlier conversion was
identified. The conversion procedure was corrected on 23 June 2026, the evaluation
volumes were reconstructed, predictions were regenerated, and all orientation-affected
earlier evaluation results were superseded.
3D Thoracic OAR Segmentation Comparison 57
The executable nnU-Net planning metadata specified a target spacing of 3.00 ×
1.07421875 × 1.07421875 mm (z × y × x).
For the nnU-Net reference configuration, the patch size was 160 × 128 × 80 voxels and
the batch size recorded in the executable planning file was 2.
CT normalisation followed the nnU-Net preprocessing configuration. The executable
dataset fingerprint recorded foreground bounds of 0 and 170 on the stored model-ready
intensity scale, with a mean of 71.95 and standard deviation of 67.63. Because the
preserved conversion metadata do not establish that this scale corresponds directly to
unmodified native Hounsfield units, these values are treated as model-ready intensity
statistics rather than native-HU thresholds.
Spatial and intensity augmentation in the reference workflow included the standard
nnU-Net operations, such as rotation, scaling, Gaussian noise and blur, brightness and
contrast modification, simulated low resolution, gamma transformation and mirroring.
2.4. Compared segmentation configurations
The benchmark compared four contemporary three-dimensional segmentation
configurations. Their principal experimental characteristics are summarised in Table 1.
Table 1. Experimental configuration of the four segmentation arms.
Model
Initialisation
Patch / batch
Sampling
Initial
learning
rate
Training characteristic
nnU-
Net v2
Standard
nnU-Net
160×128×80 /
2
nnU-Net
default
Framewo
rk
configura
tion
Long-budget reference;
best validation EMA
pseudo-Dice checkpoint
near epoch 377
STU-
Net-S
Random
160×128×80 /
2
Foreground
oversampling
= 1.0
0.01
12-hour training cap
MedNe
Xt-S
Random
160×128×64 /
1
OAR-centred
crops
0.01,
SGD
12-hour training cap;
sliding-window inference
STU-
Net-B
TotalSegmen
tator
pretrained
160×128×80 /
1
Foreground
oversampling
= 1.0
0.001
12-hour fine-tuning cap
The nnU-Net reference used a six-stage three-dimensional PlainConvUNet with
feature widths of 32, 64, 128, 256, 320 and 320, instance normalisation and leaky-
ReLU activation. STU-Net-S represents the smaller scalable U-Net configuration
and was trained without TotalSegmentator pretraining. MedNeXt-S represents a
modern convolutional alternative employing ConvNeXt-inspired volumetric blocks
and larger convolutional kernels. The local implementation used a smaller patch
depth and organ-centred cropping because of computational and memory
58 Denisa-Daniela FRIMU-PASCU, Ciprian DOBRE
requirements. Finally, STU-Net-B combines a larger STU-Net configuration with
supervised initialisation from TotalSegmentator-derived weights.
The experiment should therefore not be interpreted as a pure architecture ablation.
The models were evaluated on a common task and fixed evaluation cohort, but
training duration, initialisation, patch geometry, sampling and batch size were not
identical. The results consequently describe the performance of the tested
architecture-and-training recipes rather than proving intrinsic superiority of one
architecture independent of training conditions.
2.5. Model selection and evaluation governance
Checkpoint selection for each arm was based on validation evidence rather than
evaluation-cohort performance. No within-arm hyperparameter or checkpoint
selection was performed using the final evaluation cohort.
The complete four-model research programme developed sequentially during the
doctoral work and was not a prospectively blinded architecture trial. The fixed-
cohort designation therefore refers to stable final evaluation membership and
validation-based model selection rather than to prospective preregistration of all
four experiments.
One experimental fold and one recorded seed were available for each final model
configuration.
2.6. Quantitative evaluation
The Dice similarity coefficient was used as the principal overlap metric:
Dice = 2TP / (2TP + FP + FN)
where TP, FP and FN denote true-positive, false-positive and false-negative
segmented voxels, respectively.
Additional evaluation outputs included intersection over union, precision, recall, F1
and a common benchmark HD95 output. Because the exact implementation and
physical-unit handling of the preserved aggregate HD95 output could not be
completely reconstructed, HD95 was retained only as secondary within-benchmark
evidence and was not used for external numerical comparison.
For each organ, performance was calculated only among patients for whom a valid
ground-truth contour was available.
When valid ground truth was present but no corresponding overlap was obtained,
Dice contributed zero to the overlap analysis. Cases without a clinical contour were
excluded from conventional organ-level Dice aggregation.
The benchmark also recorded how often a model generated a structure for a case in
which no clinical annotation for that structure was available. This quantity is
3D Thoracic OAR Segmentation Comparison 59
referred to here as prediction-without-annotation rate, rather than conventional
false-positive rate, because an unlabelled organ may still be anatomically present.
The principal aggregate endpoint was the unweighted mean Dice across the 15
structures. Each anatomical structure therefore contributed equally regardless of its
number of annotated patients.
2.7. Annotation-support sensitivity analysis
Because annotation availability differed substantially between structures, an
additional post hoc descriptive analysis evaluated whether architecture ranking was
stable when poorly supported structures were progressively excluded.
Mean Dice was recalculated for all 15 structures, then for structures with ground-
truth contours in at least 30 cases. Following this, we increased the structures with
ground-truth contours to include at least 50 cases, and finally used the four
structures with the highest annotation availability: heart, left lung, right lung and
spinal cord.
The N≥30 and N≥50 values are evidence-support filters only. They were not
defined as clinical thresholds or prospective statistical endpoints.
The statistical interpretation of this study is descriptive. No claims of statistical
superiority are made, because repeated-seed experiments, paired significance
testing and bootstrap confidence intervals were not part of the completed
benchmark.
3. Results and discussions
3.1. Overall segmentation performance
The four configurations produced different aggregate performance profiles. Table
2 summarises the principal benchmark results.
Table 2. Overall performance of the four 3D segmentation configurations.
Mean Dice, 15
structures
High-
availability Dice
Reported
aggregate
HD95*
Prediction-
without-
annotation rate
0.653
0.746
186.6
0.595
0.725
0.760
164.1
0.592
0.734
0.822
239.9
0.604
0.748
0.812
141.3
0.588
*HD95 is used only as a descriptive common-output measure within this benchmark because complete
implementation and physical-unit metadata were not available for retrospective verification.
Using the unweighted mean across all 15 structures, STU-Net-B achieved the
highest score, with a mean Dice of 0.748, followed by MedNeXt-S at 0.734, STU-
Net-S at 0.725, and the long-budget nnU-Net reference at 0.653.
60 Denisa-Daniela FRIMU-PASCU, Ciprian DOBRE
The improvement of the later configurations over the nnU-Net reference was not
uniform across all organs. Importantly, the model with the highest overall mean
was not the same model that produced the highest performance on the four
structures with the greatest annotation availability. MedNeXt-S obtained 0.822 on
this subset compared with 0.812 for STU-Net-B.
This already indicates that an overall benchmark average is insufficient to
characterise the relative strengths of the models.
3.2. Organ-specific performance
Table 3 presents the mean Dice for each anatomical structure and explicitly reports
the corresponding number of available ground-truth cases.
Table 3. Organ-specific mean Dice and structure-specific annotation support.
Structure
N with
GT
nnU-Net
STU-Net-S
MedNeXt-S
STU-Net-B
Heart
150
0.845
0.874
0.873
0.844
Left lung
143
0.652
0.694
0.710
0.778
Right lung
142
0.711
0.688
0.910
0.830
Spinal cord
159
0.776
0.784
0.796
0.794
Esophagus
64
0.606
0.627
0.643
0.646
Liver
61
0.902
0.917
0.918
0.911
Left kidney
57
0.814
0.851
0.842
0.823
Right kidney
54
0.829
0.829
0.830
0.834
Trachea
19
0.747
0.648
0.670
0.725
Thyroid
30
0.628
0.592
0.424
0.649
Stomach
17
0.796
0.744
0.760
0.758
Pancreas
9
0.592
0.578
0.607
0.557
Spleen
11
0.900
0.905
0.864
0.919
Aorta
9
0.000
0.730
0.745
0.754
Duodenum
8
0.000
0.420
0.416
0.400
No model dominated all structures.
STU-Net-B was numerically strongest for the left lung, esophagus, right kidney,
thyroid, spleen and aorta. MedNeXt-S led for the right lung, spinal cord, liver and
pancreas. STU-Net-S achieved the highest values for the heart and left kidney,
while the nnU-Net reference retained the highest numerical Dice for the trachea and
stomach.
The differences for several well-supported organs were very small. Heart Dice, for
example, was 0.874 for STU-Net-S and 0.873 for MedNeXt-S. Spinal-cord
3D Thoracic OAR Segmentation Comparison 61
performance ranged only from 0.776 to 0.796. Liver Dice ranged from 0.902 to
0.918. These differences should therefore be regarded as descriptive numerical
differences rather than evidence of clinically or statistically meaningful superiority.
The results instead support the broader conclusion that segmentation performance
is anatomy dependent.
3.3. Large and well-supported structures
Large anatomical structures generally achieved relatively strong segmentation
performance, although architecture-specific variation remained evident.
The liver produced Dice values above 0.90 for every architecture. Heart
performance was similarly consistent, ranging from 0.844 to 0.874.
Lung segmentation showed greater between-model variability. STU-Net-B
achieved the highest left-lung Dice at 0.778, whereas MedNeXt-S achieved a
markedly higher right-lung Dice of 0.910.
The MedNeXt-S left-right lung results were asymmetric, with Dice values of 0.710
for the left lung and 0.910 for the right lung. The available experimental evidence
does not establish whether this difference arose from cohort characteristics,
annotations, model behaviour, crop configuration or another pipeline component.
A causal interpretation of the asymmetry would therefore be unsupported.
3.4. Smaller and less consistently annotated structures
Performance interpretation becomes substantially less certain for structures
represented by few reference annotations. The aorta, duodenum, pancreas and
spleen had only 9, 8, 9 and 11 annotated cases, respectively. Although STU-Net-S,
MedNeXt-S and STU-Net-B generated considerably higher aortic Dice values than
the nnU-Net reference, these results are based on a very small denominator.
Similarly, duodenal Dice ranged from 0.400 to 0.420 for the later comparative arms,
but only eight cases contained a valid ground-truth contour. These results remain
useful as exploratory evidence of model behaviour but should not be interpreted as
stable population-level rankings.
The difficulty is not merely statistical. In retrospective radiotherapy data, low
annotation availability can reflect clinical contouring practice, anatomical coverage
and treatment relevance. Consequently, performance on sparsely represented
structures captures interactions among model architecture, sampling, supervision
and data availability.
62 Denisa-Daniela FRIMU-PASCU, Ciprian DOBRE
3.5. Model-ranking sensitivity to annotation support
The most important secondary finding was that the identity of the highest-scoring
model changed when the aggregate score was restricted to better-supported
anatomical structures.
Table 4. Sensitivity of mean Dice ranking to minimum structure-specific annotation support.
All 15 structures
N≥30, 9
structures
N≥50, 8
structures
Four highest-
availability
structures
0.653
0.751
0.767
0.746
0.725
0.762
0.783
0.760
0.734
0.772
0.815
0.822
0.748
0.790
0.808
0.812
STU-Net-B remains the numerical leader when all 15 structures were included and
when analysis was restricted to the nine structures represented in at least 30 cases.
However, when only structures with at least 50 available reference contours were
included, MedNeXt-S became the highest-scoring configuration, with a mean Dice
of 0.815 compared with 0.808 for STU-Net-B. MedNeXt-S also led the four
highest-availability structures, with mean Dice of 0.822 compared with 0.812 for
STU-Net-B.
Importantly, none of the underlying per-organ predictions changed during this
analysis. Only the rule determining which structures contributed to the aggregate
score changed.
This ranking reversal demonstrates that a segmentation leaderboard is partly a
property of the aggregation policy and evidence distribution, rather than solely a
property of the network architecture. For heterogeneous clinical datasets, reporting
the number of reference cases available for every organ is therefore necessary for
meaningful model comparison.
3.6. Interpretation of architectural differences
The tested architectures represent different strategies for processing three-
dimensional anatomical information.
nnU-Net provides a highly engineered self-configuring baseline. Its strength lies
not only in the U-Net topology but also in dataset fingerprinting, preprocessing,
patch planning, augmentation, optimisation and inference decisions [3].
Consequently, it remains an important reference against which newer architectures
should be evaluated.
STU-Net extends the U-Net family through systematic depth and width scaling and
was designed to benefit from large-scale supervised pretraining [4]. In the present
3D Thoracic OAR Segmentation Comparison 63
experiment, the small STU-Net-S configuration was trained from random
initialisation, whereas STU-Net-B was initialised from TotalSegmentator-derived
weights.
The higher all-structure Dice obtained by STU-Net-B is compatible with the
hypothesis that increased model capacity and transferred anatomical
representations can be beneficial for heterogeneous multi-organ segmentation.
However, the experiment cannot isolate these effects. STU-Net-B differed
simultaneously in architecture size, initialisation, batch size and optimisation
settings. The result therefore does not demonstrate that model size or pretraining
alone caused the improvement.
MedNeXt follows a different strategy. Its ConvNeXt-inspired volumetric design
uses modern residual blocks and large convolutional kernels to increase contextual
processing while retaining convolutional inductive biases [5]. Its strong
performance on the heart, lungs and spinal cord suggests that this processing
strategy can be competitive for well-represented anatomical structures.
However, the MedNeXt experiment also used organ-centred crops and a different
patch depth, meaning that the observed performance reflects the complete
architecture-and-training recipe.
This distinction is important for the interpretation of applied deep-learning research.
An architecture name is rarely the only independent variable. Preprocessing,
sampling, supervision, initialisation, optimisation, inference strategy and training
duration are part of the computational system that produces the final segmentation.
3.7. Partial annotation as an evaluation problem
Partial annotation was a major property of the clinical cohort.
A structure that is not represented by an RTSTRUCT contour cannot automatically
be treated as anatomically absent. A model prediction in such a case may represent
correct but unannotated anatomy. Calling every such prediction a false positive
would therefore overstate segmentation error.
The prediction-without-annotation rates were similar across the four
configurations, ranging from 0.588 to 0.604. These values should be interpreted
primarily as indicators of interaction between the model output and incomplete
clinical annotation, rather than as conventional anatomical false-positive rates.
The same issue potentially affects model training. No explicit missing-label mask,
marginalised loss or equivalent partial-label-aware objective could be confirmed in
the available final training configurations. Future experiments should therefore
investigate losses that distinguish unlabelled anatomy from true background, such
64 Denisa-Daniela FRIMU-PASCU, Ciprian DOBRE
as marginal and exclusion approaches developed specifically for partially
supervised multi-organ segmentation [7].
3.8. Implications for model selection
The implications are as follows. If model selection had been based exclusively on
the complete 15-organ mean Dice, STU-Net-B would have been selected. If the
priority had instead been performance on the best-supported structures, MedNeXt-
S would have been selected.
For an individual anatomical target, the preferred architecture could change again.
The practical implication is that there is no universally optimal model in the present
benchmark. Model selection should instead depend on:
• the target anatomical structures;
• the amount and quality of reference evidence available for those structures;
• the clinical or engineering endpoint;
• the consequences of missed or over-segmented anatomy;
• the computational constraints of deployment;
• the training and transfer-learning strategy;
• patient-level failure behaviour in addition to aggregate performance.
A deployment-oriented segmentation system may ultimately benefit from
architecture selection or model routing according to anatomy rather than enforcing
one network as the optimal solution for every structure.
3.9. Limitations
First, this is a single private clinical dataset and no independent external clinical
validation cohort was evaluated.
Second, one fold and one recorded seed were available for each architecture. The
experiment therefore does not quantify variability across random initialisations or
data partitions.
Third, the models were not trained with identical computational budgets. The nnU-
Net reference had a substantially longer training trajectory, while the three later
comparative arms were constrained to approximately 12 hours.
Fourth, STU-Net-B used supervised pretraining whereas STU-Net-S and
MedNeXt-S were randomly initialised. The STU-Net-B result therefore reflects
both architecture and transfer learning.
Fifth, MedNeXt-S used a different patch depth and organ-centred sampling
strategy.
3D Thoracic OAR Segmentation Comparison 65
Sixth, annotation availability varied substantially by organ. Low-denominator
results, particularly for aorta, duodenum, pancreas and spleen, should therefore be
regarded as exploratory.
Seventh, explicit partial-label-aware optimisation was not documented for the final
model-training configurations.
Eighth, the preserved aggregate HD95 implementation and physical-unit
conventions were not sufficiently complete for the metric to support external
quantitative comparison.
Finally, the benchmark provides technical segmentation evidence and does not by
itself establish clinical acceptability, treatment-planning equivalence, reduction in
clinician workload or improved patient outcomes. Those questions require
prospective clinical evaluation.
4. Conclusions
This study compared nnU-Net, STU-Net-S, MedNeXt-S and TotalSegmentator-
initialised STU-Net-B for three-dimensional multi-organ segmentation on a fixed
private thoracic radiotherapy CT cohort containing 159 evaluable cases.
STU-Net-B achieved the highest unweighted mean Dice across the complete 15-
structure ontology, with 0.748, compared with 0.734 for MedNeXt-S, 0.725 for
STU-Net-S and 0.653 for nnU-Net.
However, the ranking was not invariant. MedNeXt-S became the highest-scoring
configuration when the evaluation was restricted to structures supported by at least
50 reference contours and also led the four highest-availability structures.
The results therefore do not support the conclusion that one architecture is
universally superior. Instead, they demonstrate an interaction among architecture,
training recipe, anatomy, annotation availability and aggregation policy.
For heterogeneous real-world clinical data, architecture evaluation should
consequently move beyond a single global Dice score. Structure-specific
denominators, organ-level results and sensitivity of aggregate rankings to evidence
support should be reported explicitly.
Future work should combine repeated-seed evaluation, external validation, partial-
label-aware optimisation and systematic patient-level failure analysis. These
additions would permit a stronger distinction between genuine architectural effects
and performance differences produced by training configuration or data
composition.
66 Denisa-Daniela FRIMU-PASCU, Ciprian DOBRE
The principal engineering conclusion of this study is therefore that model selection
for three-dimensional OAR segmentation should be anatomy-aware, evidence-
aware and purpose-specific rather than architecture-name-driven.
R E F E R E N C E S
[1] O. Ronneberger, P. Fischer, T. Brox, U-Net: Convolutional Networks for Biomedical Image
Segmentation, Medical Image Computing and Computer-Assisted Intervention – MICCAI
2015, LNCS 9351, pp. 234–241, 2015. doi:10.1007/978-3-319-24574-4_28.
[2] Ö. Çiçek, A. Abdulkadir, S.S. Lienkamp, T. Brox, O. Ronneberger, 3D U-Net: Learning
Dense Volumetric Segmentation from Sparse Annotation, Medical Image Computing and
Computer-Assisted Intervention – MICCAI 2016, LNCS 9901, pp. 424–432, 2016.
doi:10.1007/978-3-319-46723-8_49.
[3] F. Isensee, P.F. Jaeger, S.A.A. Kohl, J. Petersen, K.H. Maier-Hein, nnU-Net: a self-
configuring method for deep learning-based biomedical image segmentation, Nature
Methods, vol. 18, pp. 203–211, 2021.
[4] Z. Huang, H. Wang, Z. Deng, J. Ye, Y. Su, H. Sun, J. He, Y. Gu, L. Gu, S. Zhang, Y. Qiao,
STU-Net: Scalable and Transferable Medical Image Segmentation Models Empowered by
Large-Scale Supervised Pre-training, arXiv:2304.06716, 2023.
[5] S. Roy, G. Koehler, C. Ulrich, M. Baumgartner, J. Petersen, F. Isensee, P.F. Jäger, K.H.
Maier-Hein, MedNeXt: Transformer-driven Scaling of ConvNets for Medical Image
Segmentation, Medical Image Computing and Computer-Assisted Intervention – MICCAI
2023, pp. 405–415, 2023. doi:10.1007/978-3-031-43901-8_39.
[6] J. Wasserthal, H.C. Breit, M.T. Meyer, et al., TotalSegmentator: Robust Segmentation of 104
Anatomic Structures in CT Images, Radiology: Artificial Intelligence, vol. 5, no. 5, e230024,
2023. doi:10.1148/ryai.230024.
[7] G. Shi, L. Xiao, Y. Chen, S.K. Zhou, Marginal loss and exclusion loss for partially supervised
multi-organ segmentation, Medical Image Analysis, vol. 70, 101979, 2021.
doi:10.1016/j.media.2021.101979.
[8] L. Maier-Hein et al., Metrics Reloaded: Recommendations for image analysis validation,
Nature Methods, vol. 21, no. 2, pp. 195–212, 2024. doi:10.1038/s41592-023-02151-z.
[9] A.A. Taha, A. Hanbury, Metrics for evaluating 3D medical image segmentation: analysis,
selection, and tool, BMC Medical Imaging, vol. 15, article 29, 2015. doi:10.1186/s12880-
015-0068-x.